192
<<maintain>>
set aging
Syntax:
set aging <#>
Description:
To set up the age out time of dynamic learning mac.
Argument:
<#>: age-timer in seconds, 0, 10 to 65535. The value “0” means to disable aging
Possible value:
<#>: 0, 10 to 65535.
Example:
GS-2108C(mac-table-maintain)# set aging 300
set flush
Syntax:
set flush
Description:
To delete all of the MACs that is learned dynamically.
Argument:
None.
Possible value:
None.
Example:
GS-2108C(mac-table-maintain)# set flush
show
Syntax:
show
Description:
To display the settings of age-timer.
Argument:
None.
Possible value:
None.
Example:
GS-2108C(mac-table-maintain)# show
age-timer : 300 seconds
GS-2108C(mac-table-maintain)#