RUGGEDCOM RSG2488
Installation Guide
Chapter 2
Installing the Device
Grounding the Device 11
3
2
1
Figure 14: Failsafe Alarm Relay Wiring
1. Normally Open 2. Common 3. Normally Closed
Control of the failsafe relay output is configurable through the Rugged Operating System (ROS) software. One
common application for this relay is to signal an alarm if a power failure.
Section 2.4
Grounding the Device
The RSG2488 chassis ground connection uses a #6-32 screw. It is recommended to terminate the ground
connection with a #6 ring or spade lug and torque it to 1.7 Nm (15 lbf-in).
3
1
2
Figure 15: Chassis Ground Connection
1. #6-32 Screw 2. Stainless Steel Standoff 3. #6 Ring Lug
Section 2.5
Cabling Recommendations
Before connecting the device, be aware of the recommendations and considerations outlined in the following
sections:
Section 2.5.1, “Protection On Twisted-Pair Data Ports”