EasyManua.ls Logo

RuggedCom RSG2488

RuggedCom RSG2488
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RUGGEDCOM RSG2488
Installation Guide
Chapter 4
Technical Specifications
Power Supply Specifications 21
Technical Specifications
The following sections provide important technical specifications related to the device and available modules:
Section 4.1, “Power Supply Specifications”
Section 4.2, “Failsafe Relay Specifications”
Section 4.3, “Port Specifications”
Section 4.4, “Supported Networking Standards”
Section 4.5, “Operating Environment”
Section 4.6, “Mechanical Specifications”
Section 4.7, “Pin Assignments”
Section 4.1
Power Supply Specifications
Table 2: Power Supply Specifications
Input Range
Power Supply Type
Min Max
Internal Fuse Rating
Maximum Power
Consumption
a
24 VDC (Single) 13 VDC 36 VDC 10 A 40 W
48 VDC (Single) 38 VDC 72 VDC 7 A 40 W
100 VDC 300 VDC 80 W
High Voltage AC/DC
88 VAC 264 VAC
3.15 A
80 W
a
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1W less than fiber optic ports.
Section 4.2
Failsafe Relay Specifications
IMPORTANT!
The alarm switching voltage must be greater than the Safety Extra Low-Voltage (SELV) to meet safety
requirements.
Table 3: Form C Contact Relay Specifications
Parameter Value (Resistive Load)
Maximum Switching Voltage 240 VAC