3.1.3 Description of the features of the connectors and signals.
The CS-I / T interfaces to the CS-I / P through the supplied 9-pin plug-socket RS422
cable. Male connector is on the CS-I / P c RS422 female on CS-I / T. The input signals and
inlets on the CS-I / P are underneath explained:
X1 CAN BUS (5 pin M)
X2 Proportional Valve (4 pin M)
X3 Measuring inputs (6 pin M)
IN1 Control signals (12 pin M)
IN2 Signals of program selection, control and protection (12 pin M)
OUT1 Drive signals for solenoid valves and alerts (10 pin M)
OUT2 Alert signals (9 pin M)
RS422 Communication line with CS-I/T (9 pin male tank)
RS232/RS485 Communication line and programming (9 pin male tank)
M = Male footprint 2.5 Phoenix type
The input signals are activated at +24VP
The disposal of hardware signals is given in Annex A
Pin Signal Description Type
1 GNDP Reference ground for 24VP GND
2 CANH CAN high level I/O
3 SHIELD Shield (connected to ground on board) SHIELD
4 CANL CAN low level I/O
5 +24VP +24V reported to GNDP max 50 mA PWR
Table 1 – X1: CAN BUS terminal block
Pin Signal Description Type
1 +24V +24V reported to 0V max 250 mA PWR
2 0V 0V of reference for +24V GND
3 PROP(+) Signal 0-10V Proportional valve control O
4 PROP(-) 0V of reference for signal PRP_0-10 GND
Table 2 – X2: Proportional valve terminal block
Pin Signal Description Type
1 ROG Rogowski coil terminal I
2 ROG Rogowski coil terminal I
3 SHIELD Shield (connected to ground on board) SHIELD
4 VSEC - Voltage TIP negative I
5 VSEC + Voltage TIP positive I
6 SHIELD Shield (connected to ground on board) SHIELD
Table 3 – X3: Input terminal block for analogical measurement