CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:info@safcosys.it Web site: www.safcosys.it
24 of 109
4.2.3 Spot program parameters in cycles
Display window
PROGRAM N° 00
Electrodes 1 (1-4)
Current NO (NO,YES)
Working Mode D‰
Limits Check NO (NO,YES)
Pressure 1 0 (0-99%)
SV Pre Squeeze NO (NO,EV1-EV4)
Pre Squeeze 0.0 (0.0-99.0)
Pressure 2 0 (0-99%)
SV Squeeze NO (NO,EV1-EV4)
Squeeze 0.0 (0.0-99.0)
Pressure 3 0 (0-99%)
Pre Heating time 0.0 (0.0-99.0)
Pre Heating Curr. 100 (100-999‰) (D‰,V‰)
Corr. Pre Heating 1.0 (1.0-ImaxKA) (IK,EK,AD)
POWER Pre Heating 0.2 (0.2-600.0KW) (PK)
Pressure 4 0 (0-99%)
Cold time 0 0.0 (0.5-99.0)
Slope-Up 0 (0-10)
Weld Time 1 0.5 (0.5-99.0) (D‰,V‰,PK,IK)
ENERGY 1 10 (10-60000J) (EK)
Res.Decrem.Trsh. 0.1 (0.1-50.0%))(AD)
Weld Current 1 100 (100-999‰) (D‰,V‰)
Weld Current 1 1.0 (1.0-ImaxKA) (IK,EK,AD)
POWER Weld 1 0.2 (0.2-600.0KW) (PK)
Cold time 1 0.5 (0.5-99.0)
Impulse 1 1 (1-10)
Cold time 1-2 0.0 (0.0-99.0)
Weld Time 2 0.0 (0-99.0) (D‰,V‰,IK,PK,AD)
ENERGY 2 10 (10-60000J) (EK)
Weld Current 2 100 (100-999‰) (D‰,V‰)
Weld Current 2 1.0 (1.0-ImaxKA) (IK,EK,AD)
POWER Weld 2
0.2 (0.2-600.0KW) (PK)
Cold time 2 0.5 (0.5-99.0)
Impulse 2 1 (1-10)
Cold time Weld 1-2 0.5 (0.5-99.0)
Impulse Weld 1-2 1 (1-10)
Slope-Dw 0 (0-10)
Cold time 3 0.5 (0.5-99.0)
Temper Time 0 (0-999)
Temper Current 100 (100-999‰) (D‰,V‰)
Temper Current 1.0 (1.0-ImaxKA) (IK,EK,PK,AD)
Temper POWER 0.2 (0.2-600.0KW) (PK)
Hold time 0.5 (0.5-99.0)
Off time 0.0 (0.0-99.0)
Pressure 5 0 (0-99%)
Forge NO (NO,YES)
Forge Delay 0.0 (0.0-99.0)
Repeat cycle NO (NO,YES)
Initial Blanking 0.5 (0.5-10)
Curr. Max Limit 1.0 (1.0-ImaxKA) (D‰,V‰)
Curr. Min.Limit 1.0 (1.0-ImaxKA) (D‰,V‰)
Curr. Max.Limit 1 (1-30%) (IK,EK,AD)
Curr. Min.Limit 1 (1-30%) (IK,EK,AD)
P. Max. Limit 1 (1-30%) (PK)