If set to “NO”, the cycle of welding will not repeat, if set to “YES” the unit will repeat the
welding cycle, running the pre squeeze if the parameter "JMP B / A is set on B or the
squeeze if this parameter is set to "A".
Initial Blanking:
Range value: in cycles from 0.5 to 10 step 0.5
In milliseconds from 1 to 200 STEP 1
Cycles Default Value: 0.5
Milliseconds Default Value: 1
It sets the mask time during the welding time; it has impact on display and on control.
Curr. Max, P. Max Limit:
Range value: in D‰-V‰- from 1.0 to ImaxKA
in IK-PK-EK: from 1% to 30%
Default Value: 1
It sets the upper limit for the monitoring of current, power.
Curr. Min, P. Min Limit:
Range value: in D‰-V‰ from 1.0 a ImaxKA
in IK-PK-EK: from 1% to 30%
Default Value: 1
It sets the lower limit for the current, power, control during the weld.
Current Limit:
Range value: only in PK = from 1 to Imaxn (n=Electrodes number)
Default Value: : 1
Sets the maximum current at which to arrive in PK mode must always be less than Imax 1-
2-3-4 in the calibration machine
T.Weld 1 Max:
Range value: in cycles from 0.5 to 50.0 step 0.5
In milliseconds from 10 to 1000 step 1
Cycles Default Value: 0.5
Milliseconds Default Value: 10
In EK and AD, it sets the maximum time for a "good" .weld 1
T.Weld 1 Min:
Range value: in cycles from 0.5 to 50.0 step 0.5
In milliseconds from 10 to 1000 step 1
Cycles Default Value: 0.5
Milliseconds Default Value: 10
In EK and AD, it sets the minimum time to obtain a "good" .weld 1