CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:info@safcosys.it Web site: www.safcosys.it
35 of 109
T.Weld 2 Max:
Range value: in cycles from 0.5 to 50.0 step 0.5
In milliseconds from 10 to 1000 step 1
Cycles Default Value: 0.5
Milliseconds Default Value: 10
In EK and AD, it sets the maximum time for a "good" .weld (2)
T.Weld 2 Min:
Range value: in cycles from 0.5 to 50.0 step 0.5
In milliseconds from 10 to 1000 step 1
Cycles Default Value: 0.5
Milliseconds Default Value: 10
In EK , it sets the minimum time to obtain a "good" .weld (2)
Resistance Value
Range value: 0.00-650.00 uohm
Range value: 0.00
The value of resistance testing is displayed if the parameter in the VE system parameter is
set to Yes and tested if it is set differently from 0.00 uohm with parameter control limits set
to YES.
Res.Max Limit
Range value: 1-30%
Range value: 1%
Res.Min Limit
Range value: 1-30%
Range value: 1%
Meas.Elect.Close
Range value: 0.0-250.0mm (FS)
Range value 0.1
Set, if enabled, the check-tolerant positive or negative, the measure absolute or relative to
the electrodes on the closing piece.
Meas.Elect.Close Tol.+
Range value: 0.0 a 9.9mm
Range value 0.0
Positive tolerance within which there is no error on the measurement
Meas.Elect.Close Tol.-
Range value: 0.0 a 9.9mm
Range value 0.0
Negative tolerance within which there is no error on the measurement