4.2.8 Seam program parameters in milliseconds
Display windows
Program N° 0
Electrodes 1 (1-4)
Current NO (NO,YES)
Working Mode D‰
Limits Check NO (NO,YES)
Pressure 0 0 (0-99%)
Squeeze SV NO (NO,EV1-EV4)
Squeeze 0 (0-3980)
Roll Motor NO (NO,EV1-EV4)
Weld Time Delay 0 (0-1980)
Slope up Initial Curr. 0 (0-50%)
Slope Up 0 (0-200)
Pressure 1 0 (0-99%)
Weld time 1 1 (1-1980)
Cold time 1 0 (0-1980)
Weld current 1 100 (100-999‰)(D‰,V‰)
Weld Current 1 1.0 (1.0-ImaxKA)(IK)
Pressure 2 0 (0-99%)
Weld Time 2 1 (1-1980)
Cold time 2 0 (0-1980)
Weld Current 2 100 (100-999‰)(D‰,V‰)
Weld Current 2 1.0 (1.0-ImaxKA)(IK)
Pressure 3 0 (0-99%)
Weld Time 3 1 (1-1980)
Cold time 3 0 (0-1980)
Weld Current 3 100 (100-999‰)(D‰,V‰)
Weld Current 3 1.0 (1.0-ImaxKA)(IK)
Slope Dw 0 (0-200)
Slope DW Final Curr. 0 (0-50%)
Hold time 10 (10-1980)
Off time 0 (0-1980)
Initial Blanking 1 (1-200)
Curr. Max. Limit 1.0 (1.0-ImaxKA) (D‰,V‰)
Curr. Min. Limit 1.0 (1.0-ImaxKA) (D‰,V‰)
Curr. Max. Limit 1 (1-30%) (IK)
Curr. Min. Limit 1 (1-30%) (IK)
EXIT (Press +)
In seam cycle the working mode can only be be set:
D‰, V‰, IK.
where specified the () parameter is only available in the indicated
operating mode.
The Imaxs are related to the pair of electrodes selected in the
program, if the related parameter is disabled the pair is intended
“N°1”

Table of Contents