EasyManua.ls Logo

Safco CS-I 150A - System Parameters and Auto-Step

Safco CS-I 150A
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:info@safcosys.it Web site: www.safcosys.it
45 of 109
4.2.10 System Parameters
Display windows
CS-I System Parameters
Language IT (IT-EN-DE-ES)
PSw B/A Squeeze B (B-A)
JMP B/A Pre Sq. B (B-A)
Log Spots NO (NO-ALL-BAD)
N Bad Spots 0 (0-9)
Program IC1 0 (0-63)
Program IC2 0 (0-63)
Seq. Start Program 0 (0-63)
Seq. End Program 0 (0-63)
VE Input NO (NO-YES)
PV Max Volt 5 (5-10)
Pre-Stroke E.C. Open NO (NO-YES)
Pre-Stroke Time 1 (1-99)
Src/Prg key en YES (NO-YES)
S/NS key en YES (NO-YES)
End Cycle Type 0 (0-1-2)
End Cycle Time 10 (1-99)
EV Water presence YES (NO-YES)
Current source Int (Int-Ext-Bus)
Open Electrodes FLT (NO-CHK-FLT)
PSW Input SI’ (NO-YES)
S/NS Input SI’ (NO-YES)
Password NO (NO-YES)
Electrodes YES (NO-YES)
Current YES (NO-YES)
Pre Squeeze YES (NO-YES) (Only Spot)
Pre Heating YES (NO-YES) (Only Spot)
Cool time 0 YES (NO-YES) (Only Spot)
Weld 2 YES (NO-YES) (Only Spot)
Slope-Dw YES (NO-YES) (Only Spot)
Temper YES (NO-YES) (Only Spot)
Forge YES (NO-YES) (Only Spot)
Off time YES (NO-YES) (Only Spot)
Repeat cycle YES (NO-YES) (Only Spot)
EXIT (Press +)
The system parameters affect all the programs and change the characteristics of the
control.
Language:
Range value: IT; EN; DE; ES
Default value IT
This parameter allows the selection of one of four languages available:
Italian, English and German and Spanish (other foreign languages are available on
request).
PSw B/A Squeeze:
Range value: B; A
Default value B

Table of Contents