4.2.10 System Parameters
Display windows
CS-I System Parameters
Language IT (IT-EN-DE-ES)
PSw B/A Squeeze B (B-A)
JMP B/A Pre Sq. B (B-A)
Log Spots NO (NO-ALL-BAD)
N Bad Spots 0 (0-9)
Program IC1 0 (0-63)
Program IC2 0 (0-63)
Seq. Start Program 0 (0-63)
Seq. End Program 0 (0-63)
VE Input NO (NO-YES)
PV Max Volt 5 (5-10)
Pre-Stroke E.C. Open NO (NO-YES)
Pre-Stroke Time 1 (1-99)
Src/Prg key en YES (NO-YES)
S/NS key en YES (NO-YES)
End Cycle Type 0 (0-1-2)
End Cycle Time 10 (1-99)
EV Water presence YES (NO-YES)
Current source Int (Int-Ext-Bus)
Open Electrodes FLT (NO-CHK-FLT)
PSW Input SI’ (NO-YES)
S/NS Input SI’ (NO-YES)
Password NO (NO-YES)
Electrodes YES (NO-YES)
Current YES (NO-YES)
Pre Squeeze YES (NO-YES) (Only Spot)
Pre Heating YES (NO-YES) (Only Spot)
Cool time 0 YES (NO-YES) (Only Spot)
Weld 2 YES (NO-YES) (Only Spot)
Slope-Dw YES (NO-YES) (Only Spot)
Temper YES (NO-YES) (Only Spot)
Forge YES (NO-YES) (Only Spot)
Off time YES (NO-YES) (Only Spot)
Repeat cycle YES (NO-YES) (Only Spot)
EXIT (Press +)
The system parameters affect all the programs and change the characteristics of the
control.
Language:
Range value: IT; EN; DE; ES
Default value IT
This parameter allows the selection of one of four languages available:
Italian, English and German and Spanish (other foreign languages are available on
request).
PSw B/A Squeeze:
Range value: B; A
Default value B