Initial Blanking:
Range value: in cycles from 0.5 to 10 step 0.5
in milliseconds from 1 to 200 STEP 1
Cycles Default value: 0.5
Default value in ms: 1
Sets the time of masking fit during the welding time, it has impact on display and on
control.
Curr. Max Limit:
Range value: in D‰-V‰- from 1.0 to ImaxKA
in IK: from 1% to 30%
Default value: : 1
Set the upper limit for the control of welding current.
Curr Min Limit:
Range value: in D-V from 1.0 a ImaxKA
in IK: from 1% to 30%
Default value: : 1
It sets the lower limit for the control of the welding current.