CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:info@safcosys.it Web site: www.safcosys.it
43 of 109
in milliseconds from 1 to 1980 step 1
Cycles Default value: 0.5
Default value in ms: 1
It sets the weld time 3, used if cool time 3 is greater than 1, it is also used to define the test
time window, If limit control is activated.
Cool time 3:
Range value: in cycles from 0.0 to 99.0 step 0.5
in milliseconds from 0 to 1980 step 1
Cycles Default value: 0.0
Default value in ms: 0
It sets the pause time 3, if greater than 0, enable pulsation cycle.
Weld current 3:
Range value: When in D‰= from 100 to 999 (150A-300A)
from 50 to 999 (450A-600A)
When in IK = from 0.25 to Imax (150A-300A)
from 1.0 to Imax (450A-600A)
Default value in D‰ e V‰: 50/100
Default value in IK : 0.25/1.0
It sets the weld current 3 value.
Slope-Dw:
Range value: in cycles from 0 to 10
in milliseconds from 0 to 200
Cycles Default value: 0
Default value in ms: 0
It sets the decay time of the last current supplied during welding.
Slope DW Final Curr.:
The parameter sets the current end of the ramp down as a percentage of the welding
current request.
Hold time:
Range value: in cycles from 0.5 to 99.0 step 0.5
in milliseconds from 10 to 1980 step 10
Cycles Default value: 0.5
Default value in ms: 10
It sets the hold time, electrodes close with no current.
Off time:
Range value: in cycles from 0.0 to 99.0 step 0.5
in milli seconds from 0 to 1980 step 10
Cycles Default value: 0
Default value in ms: 0
Set the off time, electrodes open.