20
MX3+ v1.06 EN
© 2018 SafeLine and all the SafeLine products and accessories are copyrighted by law.
Configuration
CONFIGURATION DATA
CODE DATA COMMENTS
Enter configuration mode
00
Enter password * - - - - # Default = 0000
Exit configuration mode *00*#
ALARM CODES CODE DATA COMMENTS
P100 ID code *01* - - - - - - - - # P100 is always 8 digits
CPC ID code *02* - - - - - - # CPC 6-8 digits
Q23 ID code *03*
- - - - - - - - - - - - #
Q23 is always 12 digits
TELEPHONE NUMBERS
CODE DATA COMMENTS
1st Phone number *11* - - - - - - - - - #
Phone number to alarm receiver: 1-20 digits.
If calling through a switch board, delay time
can be set by adding asterisks between leading
number of the switchboard and telephone
number for the alarm call receiver.
Each asterisk (*) is equal to one second delay.
Example #1: *11*0**1234567#
Example #2: *11*# deletes the phone number.
2nd Phone number *12* - - - - - - - - - #
3rd Phone number *13* - - - - - - - - - #
4th Phone number *14* - - - - - - - - - #
CALL TYPE CODE DATA COMMENTS
Call type 1st number *21* - # Change the call type of the stored telephone
numbers:
0 = P100
1 = VOICE (default)
2 = Q23
3 = CPC
Change this only if your alarm operator is
using any of the mentioned protocols.
Call type 2nd number *22* - #
Call type 3rd number *23* - #
Call type 4th number *24* - #
Call type LMS number *30* - # LMS (Lift Monitoring System) call type:
0 = P100
3 = CPC (Only battery alarm)
PARAMETER LIST