V/F Patterns for Inverter Capacity 55 ~ 300kW for 230V Class*
Parameter Name Unit Factory Setting
E1-03
V/f Pattern Selec-
tion
– 0 1 2 3 4 5 6 7
E1-04
Max. Output Fre-
quency
Hz
50.0
<21>
60.0 60.0 72.0
<21>
50.0
<21>
50.0
<21>
60.0 60.0
E1-05 Max. Voltage V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0
E1-06
Max. Voltage Fre-
quency
Hz
50.0
<21>
60.0 50.0
<21>
60.0 50.0
<21>
50.0
<21>
60.0 60.0
E1-07
Mid. Output Fre-
quency
V
2.5
<21>
3.0 3.0 3.0 25.0
<21>
25.0
<21>
30.0 30.0
E1-08
Mid. Output Fre-
quency Voltage
V
13.8
<21>
13.8
<21>
13.8
<21>
13.8
<21>
40.2
<21>
57.5
<21>
40.2
<21>
57.5
<21>
E1-09
Min. Output Fre-
quency
Hz
1.3
<21>
1.5 1.5 1.5 1.3
<21>
1.3
<21>
1.5 1.5
E1-10
Min. Output Fre-
quency Voltage
V
6.9 6.9 6.9 6.9 5.7
<21>
6.9 5.7
<21>
6.9
V/F Patterns for Inverter Capacity 55 ~ 300kW for 230V Class* (Continued)
Parameter Name Unit Factory Setting
E1-03
V/f Pattern Selec-
tion
– 8 9 A B C D E F
E1-04
Max. Output Fre-
quency
Hz
50.0
<21>
50.0
<21>
60.0 60.0 90.0
<21>
120.0
<21>
180.0
<21>
60.0
E1-05 Max. Voltage V 230.0 230.0 230.0 230.0 230.0 230.0 230.0 230.0
E1-06
Max. Voltage Fre-
quency
Hz
50.0
<21>
50.0
<21>
60.0 60.0 60.0 60.0 60.0 60.0
E1-07
Mid. Output Fre-
quency
V
2.5
<21>
2.5
<21>
3.0 3.0 3.0 3.0 3.0 3.0
E1-08
Mid. Output Fre-
quency Voltage
V
17.2
<21>
23.0
<21>
17.2
<21>
23.0
<21>
13.8
<21>
13.8
<21>
13.8
<21>
13.8
<21>
E1-09
Min. Output Fre-
quency
Hz
1.3
<21>
1.3
<21>
1.5 1.5 1.5 1.5 1.5 1.5
E1-10
Min. Output Fre-
quency Voltage
V
8.0
<21>
10.3
<21>
8.0
<21>
12.6
<21>
6.9 6.9 6.9 6.9
Chapter 3 - Quick-Start Programming
Programming Menu