VG5 Installation & Quick-Start Manual 71
A.2 VG5 Monitor Display (Un-XX)
Function
Parameter
No.
Name
(Digital Operator Display)
Min.
Unit
Description
Analog
Monitor
Output Level
Parameter Access Level
V/f
V/f w/
PG
Vector
w/o
PG
Vector
w/ PG
Monitor
U1-01
Frequency Reference
(Frequency Ref)
0.01Hz The unit differs depending on O1-03 setting.
10V/Max.
output
frequency
Q Q Q Q
U1-02
Output Frequency
(Output Freq)
0.01Hz The unit differs depending on O1-03 setting.
10V/Max.
output
frequency
Q Q Q Q
U1-03
Output Current
(Output Current)
0.1A Minimum unit is 0.01 A for 7.5 kW or less.
10V/Inverter
rated
current
Q Q Q Q
U1-04
Control Method*
(Control Method)
0: V/f control
1: V/f control with PG
2: Vector control without PG
3: Vector control with PG
Q Q Q Q
U1-05
Motor Speed
(Motor Speed)
0.01Hz The unit differs depending on O1-03 setting.
10V/Max.
output fre-
quency
x Q Q Q
U1-06
Output Voltage
(Output Voltage)
0.1V —
10V/200V or
400V
?575
Q Q Q Q
U1-07
DC Bus Voltage V
(DC Bus Voltage)
1V —
10V/400V or
800V
Q Q Q Q
Monitor
U1-08
Output Power
(Output kWatts)
0.1kW —
10V/Inverter
capacity
(kW)
Q Q Q Q
U1-09
Torque Reference
(Torque Reference)
0.1% —
10V/Motor
rated torque
x x Q Q
U1-10
Input Terminal Status*
(Input Term Sts)
Q Q Q Q
U1-11
Output Terminal Status*
(Output Term Sts)
— — Q Q Q Q
0
1: T1 “Closed”
1: T2 “Closed”
1: T3 “Closed”
1: T4 “Closed”
1: T5 “Closed”
1: T6 “Closed”
1: T7 “Closed”
1: T8 “Closed”
0 0 0 0 0 0 0
1: T9~ 10 “Closed”
1: T25 “Closed”
1: T26 “Closed”
0: Not used
0: Not used
0: Not used
0: Not used
1: Fault
0 0 0 0 0 0 0 0
Appendix