EasyManua.ls Logo

Saftronics CIMR-VG5 - Page 82

Default Icon
113 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82 VG5 Installation & Quick-Start Manual
Group C Tuning
Function C1 Accel / Decel
C1-01
Acceleration Time 1
(Accel Time 1)
Depends
on
C1-10
0.00~
600.00
or
0.0
~
6000.0
Depends
on
C1-10
0.01s or
0.1s
10.0 o Q Q Q Q
C1-02
Deceleration Time 1
(Decel Time 1)
10.0 o Q Q Q Q
C1-03
Acceleration Time 2
(Accel Time 2)
10.0 o B B B B
C1-04
Deceleration Time 2
(Decel Time 2)
10.0 o B B B B
C1-05
Acceleration Time 3
(Accel Time 3)
10.0 x A A A A
C1-06
Deceleration Time 3
(Decel Time 3)
10.0 x A A A A
C1-07
Acceleration Time 4
(Accel Time 4)
10.0 x A A A A
C1-08
Deceleration Time 4
(Decel Time 4)
10.0 x A A A A
C1-09
Emergency Stop
Time
(Fast Stop Time)
10.0 x B B B B
C1-10
Accel/Decel Time
Set Unit
(Acc/Dec Units)
0.1 1 1
0: Set unit of accel/decel time is
0.01s. (0.01 Seconds)
1: Set unit of accel/decel time is
0.1s. (0.1 Seconds)
x A A A A
C1-11
Accel/Decel Time
Switching
Frequency
(Acc/Dec SW Freq)
0.0~
400.0
0.1Hz 0.0 x A A A A
Function
Parameter
No.
Name
(Digital Operator
Display)
Setting
Range
Setting
Unit
Factory
Setting
Remarks
(Digital Operator Display)
Change
during
Operation
o: Enabled
x: Disabled
Parameter Access Level
User
Setting
V/f
V/f
w/
PG
Open
Loop
Vector
Flux
Vector
Appendix
VG5 Parameters