8000m Series
- 52 -
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
FB.07 Clear length value 0:Invalid 1:Valid 0 ○
FB.08
Counter value
setting
FB.09~9999 0 ○
FB.09
Designated counter
value
0~FB.08 0 ○
FB.10
Length unit
selection
0 :Actual counting length =
displayed length* 1m
1: Actual counting length=
displayed length* 10m
0 ○
FC Group: RS485 Communication Parameters
FC.00 Local address
1~247, 0 refers to the broadcast
address
1 ○
FC.01 Baud rate selection
0:1200BPS
1:2400BPS
2:4800BPS
3:9600BPS
4:19200BPS
5:38400BPS
3 ○
FC.02
Data bit check and
format
0: No check (N, 8, 1) for RTU
1: Even parity check (E, 8, 1) for
RTU
2: Odd parity check (0, 8, 1) for
RTU
3: No check (N, 8, 2) for RTU
4: Even parity check (E, 8, 2) for
RTU
5: Odd parity check (0, 8, 2) for
RTU
0 ○
FC.03
Communication
response delay
time
0~200ms 1ms 5ms ○