EasyManuals Logo

SAJ R6 Series User Manual

SAJ R6 Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
R6 Series
- 32 -
Code
Name
A
DC Switch
B
Decompression Valves
C
DC Input
D
RS232 Communication (GPRS/ Wi-Fi /4G)
E
Ground Connection
F
RS485 Communication
G
Terminal Block
5.3 AC Connection
Table 5.3 Specifications for interface
Model
Cross-sectional area of cablesmm²
Recommender
additional grounding
cable size mm²
Scope
Recommended
value
R6-
15K/17K/20K/22K/25K-T
2-32
R6-5K/6K/8K/10K/15K-T2-
32
-LV
10.0-16.0
16.0
10
R6-25K/30K/33K/36K-T3-32
R6-20K-T3-32-LV
16.0-35.0
25.0
16
R6-36K/40K/50K-T4-32
R6-25K/30K-T4-32-LV
16.0-35.0
25.0
16
Table 5.4 Recommended power grid connecting cable and additional grounding cable specification
Note: If the grid-connection distance is too far, please select AC cable with larger diameter
as per the actual condition.
5.3.1 AC side Electrical Connection
1. Ground of the inverter. After penetrating the external hex head screw through
OT terminal of the grounding line, screw in the grounding port of enclosure of the
inverter in clockwise direction and make sure it’s screwed up tightly.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SAJ R6 Series and is the answer not in the manual?

SAJ R6 Series Specifications

General IconGeneral
CategoryInverter
Number of MPPTs2
Protection RatingIP65
THDi< 3%
CoolingNatural Convection
CommunicationRS485, Wi-Fi, Ethernet
Rated AC Voltage230V
AC Voltage Range180 V - 280 V
Rated Grid Frequency50 Hz / 60 Hz
Power Factor0.8 leading - 0.8 lagging
DC SwitchIntegrated
ProtectionDC Reverse Polarity Protection, AC Short Circuit Protection
Operating Temperature Range-25°C to 60°C

Related product manuals