SALVA INDUSTRIAL, S.A Horno Sirocco 00 Gas-Gasoil 50-60Hz (ing)121206.doc
1-9
BURNERS
These appliances incorporate a forced air burner with a premixed flame at the head whose
technical characteristics are suitable for the type of oven in which the device is to be fitted.
The type of burner which should be installed in this series of ovens is:
BURNER ( * * ) SP SR SK
Lower than
86 60 44
Nominal calorific
consumption
kW
Higher than
106 74 54
Lower than
9,2 6,3 4,7
G-20 (Nm
3
/h)
Higher than
11,2 7,8 5,7
Lower than
10,6 7,4 5,4
G-25 (Nm
3
/h)
Higher than
13 9,1 6,6
Lower than
6,8 4,7 3,5
G-30 (Kg/h)
Higher than
8,4 5,8 4,3
Lower than
6,8 4,7 3,4
Nominal Consumption
(*)
G-31 (Kg/h)
Higher than
8,3 5,7 4,2
Lower than
7,4 5,1 3,8
(*): Consumption for
C.I.P.
Diesel (kg/h)
Higher than
9 6,3 4,6
Maximum flame diameter (mm.)
240 240 140
Maximum flame length (mm.)
700 700 400
Minimum flow of the burner fan (m
3
/h)
170 120 90
Minimum scavenging time for gas (sg.)
30 30 30
Electrical rating
Voltage (V.):
Frequency (Hz.):
Phases:
230
50
I
230
50
I
230
50
I
Ignition transformator
Flame control ionization detector
Regulation On – Off
( ** ): “Lower than”: Lower limit of the burner should be lower than the indicated value.