26
4.4.1 Description of the ATEX marking
Each device is marked with the name of the manufacturer, the
reference of the device and important information for the use of the
device (air pressure, electrical power, etc.).
This equipment has been designed in accordance with the ATEX
2014/34/EU directive and is intended for use in Zone 1.
Manufacturer's brand name
II 2 G
: Use in explosive areas
II : group II 2 : category 2
Surface equipment intended for an environment in which
explosive atmospheres due to gases, vapours, mists are likely to
occur occasionally during normal operation.
G : Gas
Ex h IIB T6
Ex Marking of conformity to European standards
h : Type of protection for non-electrical appliance
IIB : Reference gas for equipment qualification
T6 : Temperature class
- Maximum surface temperature: 85°C*.
Gb : Equipment protection level (zone 1 gas)
X
Special conditions apply for safe use.
Refer to the requirements in the instruction manuals
accompanying this product.
20XX
Number given by SAMES KREMLIN.
The first two digits indicate the year of manufacture.
Max. air supply pressure of the gun
P prod : 6 bar / 87 psi
Max. fluid pressure at gun inlet
PATENT PENDING
Patent pending on Vortex technology
GSP KIT Specificity
Maximum allowable pressure in the GSP cup: 1 bar / 14 psi