10.4.7 Replace the air connection
Reminder
Objectives
Procedure to be carried out within the framework of maintenance.
Adapt the air inlet fitting of the gun to the hose in place.
Intervening staff
Qualified personnel.
Step 1
Unscrew the air connection from the gun body using the wrench
supplied with the FPro G gun.
Step 2
Install the new air connection instead.
Original equipment
Connection ¼ NPS
Option
Connection ¼ BSP,
(included in the accessories box)