9.1 Possible symptoms of faults - Causes of faults - Remedies to apply
Defaults Root causes Remedies
Paint no longer comes out of
the gun
Nozzle partially or completely
clogged
Disassemble and clean the
nozzle with solvent and a
smooth brush
Check the condition of the
seal.
The spray narrows at pump
reversals.
Viscosity too high.
Dilute the paint.
The head frequently gets dirty
Too much air.
Reduce air pressure.
The paint comes out through
the air holes in the head.
Defective nozzle seal.
Replace it.
Insufficiently tight nozzle
Tighten it.
Product leakage at the trim
level
Worn seal.
Tighten the liner press
without blocking the
needle.
If the leak is still present,
replace the seal and
needle.
Product leakage at the front of
the gun, trigger released
Impurities in the product
Worn out needle or/and worn
out nozzle
Pull the trigger 3 or 4
times and let it go back on
its own.
Replace the needle and/or
nozzle.
Air leakage at the valve
Worn valve
Changing the valve
Permanent air leakage at the
gun head when trigger is
released
Rubbing on the needle
Worn valve
Remove the trigger and
check that the needle
slides freely.
Replace the valve.