LED R&D Lab(VD)
106
Fastening M4
2-4. IER + IER-F Extension (Up to Down)
Like the vertical extension of the IER Frame, use the Joint V and for this purpose, change the Stud location of the JIG F.
However, in this case, the frames may not be aligned vertically. Accordingly, the vertical and horizontal checks are
mandatory.
Extended installation is the same as in IER.
Fasten the Joint V to the Frame to extend.
Insert the Joint V of the Frame to extend into the previous Frame for exact positioning, and then fasten the screws.
The vertical gap between Frames after extension is 1 mm.
Fig 14. Before and After Changing the JIG Stud Location
Installed Frame
Frame to Install
Fig 15. Vertical Extension
IER-F
IER-F
JOINT V
1mm
M4 SCREW