LED R&D Lab(VD)
86
8. Power and Cable Connection
• Transfer power by daisy chain with extension power cable
• Do not use Power out socket of last Cabinet
8-1. Cable connection (IER Series)
• Please check the maximum number of connections in the cabinet when connecting to the Cabinet.
• In case of powering IER and IER-F together, adjust cabinet number so that total Power consumption is under 1000W
• Make sure the quantity of connected cabinets does not exceed the recommended quantity. If the recommended quantity is
exceeded, the breaker may trip or the product may become damaged due to over-current.
※ Samsung Electronics is not responsible for problems caused as a result of exceeding the recommended quantity of connections.
• The rated voltage for the product and the rated current for the outlet can be found in the label attached on the rear of the product.
Model IER / IFR IER-F / IFR-F
Pitch P1.5 P2.0 P2.5 P4.0 P1.5 P2.0 P2.5 P4.0
Max Power consumption (W) 260 / 360W 180 / 260W 150 / 260W 150 / 260W 80 / 90 W 60 / 80 W 50 / 80 W 50 / 80 W
Max Num. of
Cabinets
110V 2 / 1 set 3 / 2 set 4 / 2 set 4 / 2 set 7 / 7 set 10 / 7 set 10 / 7 set 10 / 7 set
220V 4 / 3 set 6 / 4 set 7 / 4 set 7 / 4 set 15 / 15 set 20 / 15 set 20 / 15 set 20 / 15 set