LED R&D Lab(VD)
87
1) If cabinets are installed on a dedicated wall mount, the cabinets are fastened toward
the bottom-left direction. Sets can only be installed in the left-to-right direction.
→ The set installation direction may be different from the cable connection direction.
2) After installing all cabinets for one row, connect the signal and power cables and turn
on the sets to check that there is no problem with connection before installing
cabinets for the next row.
3) To connect cables between upper and lower sets, first connect the cables to the lower
sets before assembling the upper sets.
→ If installing upper and lower sets together before connecting cables, it is difficult to
connect cables to the lower cabinets.
3) The two Video Out ports on the Interface Gender should be connected to the first and
last cabinets by using OCM cables so as to ensure proper redundancy operation.
→ The Interface Gender should be installed in the middle on the left end of the LED
wall. (See page 13.)
→ The distance between the first and last cabinets should be within 2 to 4 m to be
connected with OCM cables.
8. Power and Cable Connection
8-2. Precautions during cabinet installation and cable connection (Full Front)