LED R&D Lab(VD)
30
4. Frame Installation
Precautions when tightening screws
Make sure you check the location of the wood stud
inside the wall before screwing screws into the wall.
Minimum wood stud size: 51 x 102 mm (2 x 4 inches)
Drill holes (3 mm) before screwing screws into the wall.
Make sure you drill screw holes in the middle of the
wood stud.
If you screw a screw directly into the wood stud without
drilling a hole, the wood may crack.
Standard wood stud interval of 16” is supported. (24” is
not supported.)
Samsung Electronics is not responsible for
problems caused as a result of failure to follow the
requirements specified in the installation guide.
Installation requirements
Sufficiently thick concrete or design wall
Wood stud inside a plaster board, or MDF wall
Frames can be installed on a sufficiently thick concrete or
interior wall. Refer to the following figures.
If installing frames on a wall that is
not flat, irregular openings may
develop and affect the exterior
appearance.
Standard installation requirements by wall type
Check the wall type before installation.
First check the wall
specifications (e.g. type,
thickness, floor plan).
Wall
Equipped with stiffeners,
e.g.
MDF or PW (plywood)
MDF, PW
(plywood)
MDF, PW (plywood)
MDF, PW (plywood)
At least 10 mm
At least 50 mm
At least 30 mm
At least 10 mm
At least 30 mm
At least 10 mm
MDF, PW (plywood)
At least
25 mm
At least
25 mm
MDF, PW
(plywood)
(except the
plaster board
thickness)
Concrete
composite wall
(except the
plaster board
thickness)
At least
50 mm
Art Wall
Concrete