TROUBLESHOOTING
5) If F Sensor has trouble
Bad contact of connector/ insert correctly
Are MAIN PCB
Connector CN30 to CN75
inserted correctly?
Is F Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN30#3(Red) to
CN1#3(Black) normal?
Is the input voltage of
IC01 MICOM #52 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Recheck the wiring connection
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder
NO
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
** Measuring point of resistance value according to
Sensor **
F : CN30#3 ↔ CN75#1 measuring resistance value
** 0Ω: Short trouble / ∞Ω: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #52,
CN30#3(Red) and CN1#3(Black) from
PCB typical Ground part are similar.
☞ Checking method of F Sensor resistance
CN30#3(Red) ↔ CN75#1(Gray)
- Compare the temperature table after the measure
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
F
Connector CN30#3(Red) to
CN1#3(Black) PCB typical Ground
☞ Checking method of F Sensor voltage
- Measure the voltage of Sensor Check Point #1(IC01 MICOM #52)
on PCB or CN30#3(Red) ↔ CN1#3(Black)
- Compare the temperature table after the measure
Measuring voltage of CN30#3(Red) ↔ CN1#3(Black) are below.
typical PCB Ground
CN1#3(Black)
2¢(-17¡) is recommended 38¢(3¡) is recommended
Start
YES
YES
YES