FUNCTIONAL DESCRIPTION
Exposure
Main Menu/Camera Setting/Exposure
The Exposure settings are to control the camera’s
exposure meter.
Brightness :
Adjusts the screen brightness.
(Over 32: Brighter, Under 32: Darker)
It may not fully operable under extremely low lighting
condition.
Iris :
AUTO :
Automatically adjusts the exposure meter.
MANUAL : Enables manual adjustment of the
exposure meter. (Over 32: Brighter,
Under 32: Darker)
Shutter : Controls the camera’s electronic shutter.
OFF : The shutter speed is fi xed at 1/60 for
NTSC and 1/50 for PAL. Operates when
Iris is on the Auto Mode.
A.FLK : Select this setting when you experience
picture fl ickering. Flickering can happen
when artifi cial lighting frequencies clash
with camera frame rates.
MANUAL : Enables manual adjustment of the
shutter speed.
Sens-Up :
AUTO : Automatically detects light levels and
maintains a clear picture at night or
under low-light conditions.
SENS-UP LIMIT : Adjusts to the maximum-
powered zoom per frame.
While the Internal Sync mode is in effect, setting the shutter to '---' and facing the
camera directly to a bright light source may cause poor camera performance.
Brightness is disabled when the Iris is in Manual mode.
Shutter is disabled when the WDR is turned on.
Sens-Up is disabled when the shutter is in Manual mode.
-
-
-
-
-
-
-
M
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Camera Setting
Zoom/Focus
White Balance ATW(IN)
Exposure
Back Light OFF
AGC ---
DNR MEDIUM
XDR OFF
Day/Night
Others
Exposure
Brightness 32
Iris AUTO
Shutter OFF
Sens-Up AUTO