4th Edition of TEMI880 IM : Jan. 29. 2007 Page 31 / 119
2.7 Operation Setting Screen
This is the screen about additional function of the general machine and additional setting at Fix Run.
Figure 2-16. Operation Setting – First Screen Figure 2-17. Operation Setting – Second Screen
No. Contents Description Additional Description
1
Operation
Mode
Select Program mode or Fix
mode.
PROG : 2.6.1 Program Stop Screen
FIX : 2.6.3 Fix Stop Screen
It isn’t changed at the running.
The running after power on
Before
Power Off
PROG/FIX
STOP
PROG RUN
FIX
RUN
STOP
PROG/FIX
STOP
PROG STOP
FIX
STO
P
COLD
PROG/FIX
STOP
Run from first
segment.
FIX
RUN
2
Power Mode
Setup when re-start
after power off.
Recognize to power off if it is
more than 3 seconds.
If re-start before 3 seconds,
It will run to Hot mode
Automatically.
HOT
PROG/FIX
STOP
Run from running
segment time
before power off.
FIX
RUN
3
Fuzzy Select
Control over shoot by fuzzy
select.
4
Key Lock Key Lock/Unlock.
5
Light Off Set time of the backlight. Backlight time is setting 10 minutes.
6
Operation
Hour(H)
Set Hour.
7
Operation
Minute(M)
Set Minute.
8
Time Mode Set Time Mode On/Off.
OFF : Fix running is stopped at the
STOP button clicked.
ON : It is stop after running time
(set
6,
7 ) automatically.
9
Temp. Slope Temp. up/down slope.
10
Humi. Slope Humi. up/down slope.
Temp./Humi. value goes to the SP gradually.
It is applied both of up and down.
3
1
2
4
5
8
6
7
9