1 Remove 4 screws A and take the LCD/Prism assy off upward from the
optical unit.
2 Remove each screw B and take the glass off upward.
Polarized
Glass-Out
LCD Panel/Prism
Assy
LCD Panel/Prism Assy
Fig.7-
2
* Should be place the glass as the
film attached side comes to the
LCD panel side.
LCD Panel
Note:
Do not replace the LCD panel
separately otherwise it can
not obtain proper picture.
1 Remove 9 screws to take the Optical Unit Top off upward.
Fig.7-1
Fig.8
Polarized Glass-Out removal
Optical Unit Top removal
Optical Parts Disassemblies
B
A
A
A
Optical Unit Top