EasyManua.ls Logo

Sanyo PLC-ET30L - No Sound

Sanyo PLC-ET30L
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-80-
Troubleshooting
INPUT1
INPUT2
INPUT3
IC5001
AUDIO-SW
<NJW1141>
AV JOINT
MAIN
Q1363
Q1361
SPEAKER
SP901
L,R
L,R
L,R
1,30
10
21
13
14
4
1
2,29
3,28
AUDIO
OUT
L,R 9,22
Q5031
K40E K30A
Q5032
Q5041/Q5042
Q5151
Q5141
Q5042
Q5047
IC5121
AUDIO
OUT
<LM4889>
1
3
K8H
IC301
SCAN
CONVERTER
&
SYSTEM
CONTROL
<PW392>
SCL0_S5V
AUDIO_OUT_DET
SDA0_S5V
PW_SCL0
PW_SDA0
SCL0_S5V
SDA0_S5V
355
444
439
AUDIO
MUTE
MUTE
Mute On: H
33
34
73
74
71
72
37
38
41
42
K30B K8S
87
88
45
46
47
48
53
54
79
80
No Sound
(Check audio signal processing stage)
Check mute signal.
H; Mute on
Is audio signal
observed?
Check
AUDIO_OUT_DET
signal.
H; Mute on
Is audio signal
observed?

Table of Contents