EasyManua.ls Logo

Sanyo PLC-XF47 - Page 45

Sanyo PLC-XF47
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 45 -
13-5
Polarized units removal.
1. Remove 6 screws-A and remove the Polarized glass units.
Blue and Green Polarized unit
2. Remove screw-B, remove the plate (A) and remove the
Prepolarized glass (IN).
3. Remove screw-C and remove the Optical filter unit.
Remove screw-F, remove the sheet and remove the
Temp. sensor (Z8P & TH).
Remove screw-E, remove the Plate (C) and remove the
Optical filter.
4. Remove 2 screws-D, remove the plates (B) and remove
the Polarized glass (IN).
Red Polarized Units
2. Remove screw-B, remove the plate (A) and remove the
Prepolarized glass (IN).
3. Remove screw-C and remove the Optical filter unit.
Remove screw-E, remove the Plate (C) and remove the
Optical filter.
4. Remove 2 screws-D, remove the plates (B) and remove
the Polarized glass (IN).
Optical Unit disassemblies
A
A
A
A
A
A
B
D
D
C
B
D
D
C
Temperature sensor
(PTH901)
Prepolarized glass (IN)
E
Plate (A)
Plate (B)
Plate (B)
Holder (A)
Polarized glass (IN)
Optical filter unit
Optical filter
Plate (C)
Prepolarized glass (IN)
(Inorganic polarizer)
Plate (A)
Holder (A)
Plate (B)
Polarized glass (IN)
Plate (B)
Optical filter unit
E
F
Optical filter
Plate (C)
Temp. sensor
and Sheet
(Only Blue)
Red
Blue
Green