-48-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
PLC-XK2600
Group
253
Fan Tem Error Setting (Memorized)
Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 Temp A Warning (High) 45 51 47/48 49/50 -
On1/On2
1 Temp B Warning (High) 58 63 58 63 -
2 Temp C Warning (High) 63 68 63 68 -
3 Temp B-A Warning(High) 100 100 100 100 -
4 Temp C-A Warning(High) 100 100 100 100 -
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
45 50 46
/
47 48/49 30-100
On1/On2
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
58 63 58 63 30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
63 68 63 68 30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
45 46 46 47/48 30-100
On1/On2
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
58 58 58 58 30-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
62 62 62 62 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5 0-100
16
Temp B Warning Offset
(Temp)
5 0-100
17
Temp C Warning Offset
(Temp)
5 0-100
18
Temp B-A Warning Offset
(Temp)
0 0-100
19
Temp C-A Warning Offset
(Temp)
0 0-100
20
Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
3 0-5
21
Temp B Warning Offset
(Time)
3 0-5
22
Temp C Warning Offset
(Time)
3 0-5
23
Temp B-A Warning Offset
(Time)
3 0-5
24
Temp C-A Warning Offset
(Time)
3 0-5
PLC-XK2200
Group
254
Fan Control Range Setting (Temp./Voltage)
Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp 33 35 33/34 35/36 -
On1/On2
1 High Fan Control Max Temp 40 46 40/42 43/44 -
On1/On2
2 High Fan1 Min 68 68 83/93 85/95 -
On1/On2
3 High Fan1 Max 135 135 135 135 -
4 High Fan2 Min 73 85 88/100 101/113 -
On1/On2
5 High Fan2 Max 96 101 112/124 117/129 -
On1/On2
6 High Fan3 Min 75 80 85/100 90/105 -
On1/On2
7 High Fan3 Max 135 135 135 135 -
10 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp.
at Normal
33 35 33/34 35 20-100
On1/On2
11
Normal Fan Control Max
Temp.
40 45 40/41 42/43 20-100
On1/On2
12 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
58 58 80/90 85/95 0-255
On1/On2
13 Normal Fan1 Max 135 135 135 135 0-255
14 Normal Fan2 Min 71 81 95/107 106/118 0-255
On1/On2
15 Normal Fan2 Max 108 113 132/144 137/149 0-255
On1/On2
16 Normal Fan3 Min 70 75 85/100 90/105 0-255
On1/On2
17 Normal Fan3 Max 135 135 135 135 0-255
20 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp.
at Eco
34 35 32/33 34 20-100
On1/On2
21 Eco Fan Control Max Temp 45 46 40 41/42 20-100
On1/On2
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
50 50 65/70 70/75 0-255
On1/On2
23 Eco Fan1 Max 147 147 125 125 0-255
24 Eco Fan2 Min 45 45 48/60 48/60 0-255
On1/On2
25 Eco Fan2 Max 73 80 68
/
80 73/85 0-255
On1/On2