Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
26 Eco Fan3 Min
Fan voltage value at Eco (unit: 0.1V)
55 60 60/75 65/80 0-255
On1/On2
27 Eco Fan3 Max 135 135 115 115 0-255
PLC-XK2600
Group
254
Fan Control Range Setting (Temp./Voltage)
Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp 33 35 33/34 35/36 -
On1/On2
1 High Fan Control Max Temp 40 46 40/42 43/44 -
On1/On2
2 High Fan1 Min 68 68 83/93 85/95 -
On1/On2
3 High Fan1 Max 135 135 135 135 -
4 High Fan2 Min 75 85 88/100 98/110 -
On1/On2
5 High Fan2 Max 100 105 113/125 118/130 -
On1/On2
6 High Fan3 Min 80 85 85/100 90/105 -
On1/On2
7 High Fan3 Max 135 135 135 135 -
10 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp.
at Normal
33 35 33/34 35 20-100
On1/On2
11
Normal Fan Control Max
Temp.
40 45 40/41 42/43 20-100
On1/On2
12 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
58 58 80/90 85/95 0-255
On1/On2
13 Normal Fan1 Max 135 135 135 135 0-255
14 Normal Fan2 Min 73 85 88/100 101/113 0-255
On1/On2
15 Normal Fan2 Max 96 101 112/124 117/129 0-255
On1/On2
16 Normal Fan3 Min 75 80 85/100 90/105 0-255
On1/On2
17 Normal Fan3 Max 135 135 135 135 0-255
20 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp.
at Eco
34 35 32/33 34 20-100
On1/On2
21 Eco Fan Control Max Temp 40 41 40 41/42 20-100
On1/On2
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
50 50 60/70 65/75 0-255
On1/On2
23 Eco Fan1 Max 120 120 125 125 0-255
24 Eco Fan2 Min 45 45 48/60 48/60 0-255
On1/On2
25 Eco Fan2 Max 65 70 68/80 73/85 0-255
On1/On2
26 Eco Fan3 Min 55 60 60/75 65/80 0-255
On1/On2
27 Eco Fan3 Max 110 110 115 115 0-255
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt 55 0-255
1 Fan2 Initial Volt Fan Start Voltage(0.1V) 55 0-255
2 Fan3 Initial Volt 55 0-255
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
135 0-255
5 Fan2 Cooling Speed 100 0-255
6 Fan3 Cooling Speed 135 0-255
8 Cooling Time L1
Cooling Time setting at Fan Mode L1
(x 30 sec) 1: 30, 3: 90, 15: 450 sec.
2 1-15
9 Cooling Time L2
Cooling Time setting at Fan Mode L2
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
3 1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
3 1-15
11
OnStart Cooling Start Thresh-
old
38 0-100
12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1
Group
256
Fan/Lamp Voltage Dimmer Setting
2 Fan 1 Speed Gain 10 0-255
3 Fan 2 Speed Gain 10 0-255
4 Fan 3 Speed Gain 10 0-255
Group
257
Fan Dimmer Setting
0 Dimmer Average Chech Period
Dimmer Average measurement
Time (0:10sec. 1:30sec. 2:60
sec. 90:sec...10:30sec.)
0 0-10
1 Dimmer Average
Dimmer Average Value (Read
only)
-
2 Last Voltage Difference -
3 Voltage Difference Goal -
Group
258
Fan Network IC temperature rising resolve
0
Standby Cooling Check Cycle
9999
1
Standby Cooling Start Threshold
9999
2 Standby Cooling Enable 9999