EasyManua.ls Logo

Sanyo PLC-XL50A - Page 59

Sanyo PLC-XL50A
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 59 -
Service Adjustment
Group/
Item
Item Name Function Initial Range Note
Group 256 Fan Lamp Voltage Down Setting
0 Lamp Voltage
Current Lamp Voltage (0.1V)(Read
only)
- 0-255
1 Lamp Vol Threshold
Threshold to judge Lamp Voltage
Down ( V×10)
30-90
2 Fan1 Speed Gain
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
0-255
3 Fan2 Speed Gain 0-255
4 Fan3 Speed Gain 0-255
5 Not used 9999 -
Group 257 Fan Dimmer Setting
0 Dimmer Average Check Period
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, 2:60sec, 3: 90sec
...10:300 sec)
1 0-10
1 Dimmer Average Dimmer Avarage Value (Read only) -
2 Last Voltage Dierence Read only -
3 Voltate Dierence Goal Read only
Group 258 Fan IC Temp for Netowrk model
0 Not used.
1 Not used.
2 Not used.
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when
changiing the Value (PC White 100%)
1 Loop Count
Maximum Execution Times (OFFSET-
>GAIN)
10 1 - 30
2 Auto Status
Result of Auto-Calibration (Last
Memory)
0 0 / 1 / 9 0: OK, 1: Adjusting,9: Error * ReadOnly
3 AutoWait Wait Value for each setting 1 1 - 20
4 CHECK -Tolelance Torelance of OFFSET 2 1 - 255
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START
Black Level Acquiring Area H-Start
Position
975 0 - 1000
1 OFFSET AREA V START
Black Level Acquiring Area V-Start
Position
500 0 - 1000
2 GAIN AREA H START
White Level Acquiring Area H-Start
Position
25 0 - 1000
3 GAIN AREA V START
White Level Acquiring Area V-Start
Position
500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT
Black/White Level Acquiring Area
Height
9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 3 0 - 127
7 OFFSET torelance Torelance of Black Level Adj. 1 1 - 127
8 GAIN target Target Value of White Level Adj. 238 0 - 255
9 GAIN torelance Torelance of White Level Adj. 1 1 - 255
Group 262 Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X Y Acquiring Area H-Start Position 20 0 - 1000
1 Y Image Area Start Y Y Acquiring Area V-Start Position 200 0 - 1000
6 Image Area H Width Image Level Acquiring Area 8 0 - 4095
7 Image Area V Hight Image Level Acquiring Area Height 9 0 - 4095
8 Y Target Level Target Value of Y Level Adj. 217 0 - 255
11 Gain Tolerance Torelance of Level Adj. 1 0 - 255
12 Delta Gain Deviation Width of Gain Value 9 0 - 255
Group 264 Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START
Y - Oset Acquiring Area H-Start
Position
925 0 - 1000
1 Y-OFFSET AREA V START
Y - Oset Acquiring Area V-Start
Position
500 0 - 1000
2 CB - OFFSET AREA H START
CB - Oset Acquiring Area H-Start
Position
925 0 - 1000 If not used: use Y's value
3 CB - OFFSET AREA V START
CB - Oset Acquiring Area V-Start
Position
500 0 - 1000 If not used: use Y's value
4 CR - OFFSET AREA H START
CR - Oset Acquiring Area H-Start
Position
925 0 - 1000 If not used: use Y's value
5 CR - OFFSET AREA V START
CR - Oset Acquiring Area V-Start
Position
500 0 - 1000 If not used: use Y's value
6 Y - GAIN AREA H START Y 50 0 - 1000
7 Y - GAIN AREA V START 500 0 - 1000