-34-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
148
V-Line Shading Comp. Value
Setting [B4 dot]
Normal-Mount / Rear-Ceiling 16 /16 0 - 31
149
V-Line Shading Comp. Value
Setting [B5 dot]
Normal-Mount / Rear-Ceiling 16 /16 0 - 31
150
V-Line Shading Comp. Value
Setting [B6 dot]
Normal-Mount / Rear-Ceiling 16 /16 0 - 31
Group 200 Option
0
Logo Prohibition (Forced No Brand)
Logo Prohibition (0: Menu, 1: Forced, 2:
China, 3-9: not used)
0 0 - 2 Effective after AC On
1 RS232C Baudrate Baud Rate 0 0 - 2 0: 19200bps, 1: 9600bps, 2: 115200bps
2 PJLink Enable PJLink 0 0 - 1 0:Disable 1:Enable
3 Shipping Setting 0 0 - 20 Default set when the value is set to 10
4 CABLE SW Long Cable 0 0 - 10 0: Disable, 1: Enable
5 PW Debug Command Enable 0 0 - 1
0:Disable (Sanyo Serial Command Eanble)
1: Enable (PW Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal), 1:Disable
No last memory
20 Projector Time Reset 0 0 - 20
Projector Time is cleared when the value is
set to 10
21 Lamp Warning Time (NORMAL)
Lamp Life at Normal Mode (Warning Time at
Normal)
500 - 8000
22 Lamp Warning Time (ECO)
Lamp Life at Eco Mode (Warning Time at
Eco)
500 - 8000
23 Lamp Warning Time (HIGH)
Lamp Life at High Mode (Warning Time at
High)
500 - 8000
30 Lamp life test enable 0:Disable 1:Enable, for safety test only
31 Lmap On time(for life test) For test purpose
32 Lamp Off time(for life test) For test purpose
33 Lamp total time(for life test) For test purpose
40 PreScaler 0-255 n/a
41 Htime 0-65535 n/a
52 Lamp Counter reset Times Reset Times of Lamp Counter 0 0 - 255 Read only
54 Factory Default Execute Times Reset times of Fanctory Default 0 0 - 255 Read only
55 Motor Disable 0: On, 1: Off 0 0 - 1
56 Menu Position Move menu (X asis) 0 0 - 1024
57 Menu Position Move menu (Y asis) 0 0 - 1024
60 Spread Spectrum Enable 1 0 - 1 0: Off, 1: On
61 Spread Spectrum Frequency 80 0 - 500
62 Spread Spectrum Amplitude 100 0 - 300
Group 201 Option (signal)
0 FrameLock Option 0 0 - 1
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and 47Hz
(Vfreq) ~ Panel frequency of input signal
2 Field Sense Invert Enable 0 0 - 1
Reverse Processing of FLDINVSetting Value
0: Disable - Used FLDINV Setting Value
1: Enable - Used Reversed FLDINV Setting
Value
3
4 Sub Image Enable 1 0 - 1
0:Disable (Service Adjustment Dsiable,
Used all the Center Values
1:Enable (Service Adjustment Enable)
6 Zoom Accelerator Enable 0 0 - 1
0:Zoom Accelerator OFF,
1:Zoom Accelerator ON
No last memory
7 DZoom Reset by Keystone 0 0 - 1
0:Enable (Normal), 1:Disable (Dzoo is not
cancelled even if Keystone is cancelled)
No last memory
8 Stability Count Count Value of V-missing 5 0 - 255
9 Sensivity for Signal Lost (HSYNC)
Only used this value for No Signal
Judgement(Hz)
350 0 - 65535
10 Sensivity for Signal Lost (VSYNC)
Only used this value for No Signal
Judgement(Line)
3 0 - 255
11 Keystone Filter Center Value 16 0 - 30
Group 210 LampContorl
0 DIMMER_CTRL_LEVEL1
Luminance Level 1 Data for Dimmer: Dim
Level 1 at the less than the Value
9 0 - 255 Philips 200W
1 DIMMER_CTRL_LEVEL2
Luminance Level 2 Data for Dimmer: Dim
Level 2 at the less than the Value
18 0 - 255
2 DIMMER_CTRL_LEVEL3
Luminance Level 3 Data for Dimmer: Dim
Level 3 at the less than the Value
26 0 - 255
3 DIMMER_CTRL_LEVEL4
Luminance Level 4 Data for Dimmer: Dim
Level 4 at the less than the Value
35 0 - 255
4 DIMMER_CTRL_LEVEL5
Luminance Level 5 Data for Dimmer: Dim
Level 5 at the less than the Value
44 0 - 255
5 DIMMER_CTRL_LEVEL6
Luminance Level 6 Data for Dimmer: Dim
Level 6 at the less than the Value
53 0 - 255