-37-
Group/
Item
Item Name Function Initial Range Note
91 FAN_2_AUTO_ADJ 0: OFF (Manual), 1: ON (Auto) - 0-1
92 FACTORY_STD_FAN_VOL_MIN
For Factory Adjustment Ref FAN Voltage Min
(Initial 5V)
50 / 50
0-255
93 FACTORY_STD_FAN_VOL_MAX
For Factory Adjustment Ref FAN Voltage Min
(Initial 13.5V)
135 / 135
0-255
94 FAN1_ADJUST_VOLT_MIN
For Factory Adjustment FAN1 Drive Voltage
Min
40 / 40
0-255 * Fan Voltage adjustment
95 FAN1_ADJUST_VOLT_MAX
For Factory Adjustment FAN1 Drive Voltage
Max
210 / 210
0-255 * Fan Voltage adjustment
96 FAN2_ADJUST_VOLT_MIN
For Factory Adjustment FAN2 Drive Voltage
Min
10 / 10
0-255 * Fan Voltage adjustment
97 FAN2_ADJUST_VOLT_MAX
For Factory Adjustment FAN2 Drive Voltage
Max
210 / 210
0-255 * Fan Voltage adjustment
98
TEMP_ERROR_DETECT_MAX_
TIMES
Temp Failure when The Sensor detects an
error X times sequentially
5 / 5
1-9
99 FAN_1_MIN_VOL_LAMP_DIFF
Up Volume of FAN1 Control Min
(Unit Vx10)
0 / 0
0-20
100 FAN_2_MIN_VOL_LAMP_DIFF
Up Volume of FAN2 Control Min
(Unit Vx10)
0 / 0
0-20
101 LAMP_VOL_BORDER_LINE
Threshold Lamp Volatge of the above items
(Unit Vx10)
70 / 70
30-90
102 LAMP_VOL
Current Lamp Voltage (V)
(Effective 30 sec. after turn on)
- / -
0-255 * Read only
103 Dimmer Voltage Change Cycle Voltage Change Cycle at Dimmer (Unit: sec) 3 / 3 1-?
104 Dimmer Average Check Period Measuring Time at Dimmer (Unit: sec) 10 / 10 1-?
105 Dimmer Voltage Change rate
Voltage Change Volume at Dimmer (Unit: 0.1V)
1 / 1 1-?
106 Dimmer Average Avarage Value of Dimmer - / - - * Read only
107 Last Voltage Difference Last Voltage defferential Value - / - - * Read only
108 Voltate Difference Goal
Target Voltage Dif. Value at Dimmer (Unit: 10V)
- / - - * Read only
109 Temp Diff Normal 0 / 0
110 Temp Diff Eco 0 / 0
111 Temp Diff Normal High 0 / 0
112 Temp Diff Eco High 0 / 0
113 Temp Diff Normal Ceil 0 / 0
114 Temp Diff Eco Ceil 0 / 0
115 Temp Up Time Normal 0 / 0
116 Temp Up Time Eco 0 / 0
117 Temp Up Time Normal High 0 / 0
118 Temp Up Time Eco High 0 / 0
119 Temp Up Time Normal Ceil 0 / 0
120 Temp Up Time Eco Ceil 0 / 0
121 Standby Cooling Check Cycle 5 / 5
122 Standby Cooling Start Threshold 54 / 54
123 SAfter Shutdown Cooling 1 / 1 0: No, 1: Yes
124 OnStart Cooling Start Threshold 38 / 38 0-100
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when changiing
the Value (PC White 100%)
1 Loop Count Maximum Execution Times (OFFSET->GAIN) 10 1 - 30
2 Auto Status Result of Auto-Calibration (Last Memory) 0 0 / 1 / 9 0: OK, 1: Adjusting,2: Error * ReadOnly
3 AutoWait Wait Value for each setting 1 1 - 20
4 CHECK -Tolelance Torelance of OFFSET 2 1 - 255
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START Black Level Acquiring Area H-Start Position 975 0 - 1000
1 OFFSET AREA V START Black Level Acquiring Area V-Start Position 500 0 - 1000
2 GAIN AREA H START White Level Acquiring Area H-Start Position 25 0 - 1000
3 GAIN AREA V START White Level Acquiring Area V-Start Position 500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT Black/White Level Acquiring Area Height 9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 3 0 - 127
7 OFFSET torelance Torelance of Black Level Adj. 1 1 - 127
8 GAIN target Target Value of White Level Adj. 238 0 - 255
9 GAIN torelance Torelance of White Level Adj. 1 1 - 255
Group 262 Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X Y Acquiring Area H-Start Position 20 0 - 1000
1 Y Image Area Start Y Y Acquiring Area V-Start Position 500 0 - 1000
6 Image Area H Width Image Level Acquiring Area 13 0 - 4095
7 Image Area V Hight Image Level Acquiring Area Height 20 0 - 4095
8 Y Target Level Target Value of Y Level Adj. 217 0 - 255
11 Gain Tolerance Torelance of Level Adj. 1 0 - 255
12 Delta Gain Deviation Width of Gain Value 9 0 - 255
Group 264 Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START Y - Offset Acquiring Area H-Start Position 900 0 - 1000
1 Y-OFFSET AREA V START Y - Offset Acquiring Area V-Start Position 500 0 - 1000
2 CB - OFFSET AREA H START CB - Offset Acquiring Area H-Start Position 900 0 - 1000 If not used: use Y's value