4
4 - 99
Mini ECO-i SYSTEM Unit Specifications
6. Ceiling-Mounted Type (T Type)
Indoor unit (E)
MODEL No. SPW-TDR364GXH56(A/B)
Power source
220 - 230 - 240 V / Single-phase / 50 Hz / 60 Hz
Controller P.C.B. Ass’y
CR-SRP50A-B (Microprocessor)
Fan (Number…diameter) mm
Centrifugal (4 … ø 140)
Fan motor
Model…Nominal output W DK8-123B280H … 80 W
Power source
340 VDC
No. of pole…r.p.m. (230 V, High) rpm 8P … 1,040
Coil resistance RED WHT : 37.0
37.0
37.0
(Ambient temperature 20°C) WHT BLK
:
BLK RED
:
Run capacitor
Safety device
VAC, µF
Thermal protector, fuse
Electronic expansion valve
Coil UKV-U030E
Coil resistance (at 20°C) ORG GRY : 46 YEL GRY : 46
RED GRY : 46 BLK GRY : 4
6
Valve body
UKV-30D33
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows…fin pitch mm 3…1.4
Face area m
2
0.326