Temperature Sensor Installation (3200/3300 Only)
(IMPORTANT: Detach clock from power source before installing new circuitry. DO NOT add new circuitry
while the clock is operating)
Attach the end of the Temperature Sensor Wire to the circuit board in the following manner:
The Sensor Cable is 6 feet (1.83 meters) long, and so the sensor should be positioned within 6 feet of
the clock. The cable is unshielded, 4 conductor, 22AWG (.33mm²). If longer than 6 feet is required, the
wire would have to be terminated in an electrical box, and the longer wire would have to be provided by
the customer.
Data from the temperature sensor will be sent to your clock when the clock is powered on. For more
information on how to make the digital clock display temperature, please see the section labeled “Web
Interface - Display Settings.
Sensor Cable
No Wire in 5
Red
Green
Black
White
1
2
3
4
5
Temperature