26
Example: Determining residual weight in percent
Parameter settings: Applic. - percent (menu code 2. 4.)
Reference percentage: Ref 100%
Step Key (or instruction) Display/Data output
1. Tare the balance
w 0.0 g
2. Changing the reference:
(see the previous page)
b ref 100
%
3. Place sample equal to 100% on the
balance (in this example: 111.6 g)
4. Start the application. u + 100.0
%
*
The current reference weight pRef 100 %
remains stored until a new Wxx% + 111.6 g
reference is set or power to the
power supply is interrupted.
5. Remove sample (e.g. for drying)
6. Place weight on the balance + 94.9
%
*
(in this example 322.5 g)
7. If desired, print percentage r Prc + 94.9 %
8. Toggle display between + 105.9 g
*
weight and percentage Repeatedly: b + 94.9
%
*
9. Clear display of residual weight c + 105.9 g
and reference percentage
Exit application
10. If desired, print net residual weight
r N + 105.9 g