Configuration (Operating Menu)
38  Cubis MSE Operating Instructions
Parameter Settings: Overview
ο = Factory setting√ = User-defined setting
          Info about 
Level 1  Level 2  Level 3    Level 4  Menu Level
 
1) Setup  BAL.SCAL.  AMBIENT conditions (adapt filter)    V.Stable Very stable  1� 1�1� 1 
  Balance   ο  STABLE  1� 1�1� 2 
  parameters    UNSTABL  1� 1�1� 3 
     V.UNSTBL. Very unstable  1� 1�1� 4
  App.Filt. Application filter  ο  FINAL.RD. Final readout mode  1� 1�2� 1 
     Filling Filling mode  1� 1�2� 2 
     REDUC. Reduced  1� 1�2� 3 
     OFF  1� 1�2� 4
  Stab.Rng. Stability range    Max. ACC. Maximum accuracy  1� 1�3� 1 
     V.ACC.  1� 1�3� 2 
    ο  ACC.  1� 1�3� 3 
     FAST  1� 1�3� 4 
     V.FAST.  1� 1�3� 5 
     Max.FAST
1
)  1� 1�3� 6
  ST.DEL� Delay  No  1� 1�4� 1 
    ο  Short  1� 1�4� 2
     AVERG.  1� 1�4� 3
     LONG  1� 1�4� 4
  Tare 
1
)  WIOSTB.W/o stability  1� 1�5� 1 
    ο WISTB.After stability  1� 1�5� 2 
     ATSTAB. At stability  1� 1�5� 3
  Aut.zero Off   1� 1�6� 1 
    Auto zero  ο on  1� 1� 6� 2
  WT.UNIT    For list of units, see   1� 1�7� 1 
    Basic weight unit    “Toggling Between Weight Units”  to 
       1� 1�7�24
  DISP.DIG. 
1
)  ο All  1� 1�8� 1 
    Display accuracy    lp.on.off (last digit after load change)  1� 1�8� 2 
     DIV.1 1 interval  1� 1�8� 6 
     Minus 1 Reduced by 1 digit  1� 1� 8� 7
  Cal./ADJ.  EXT.CAL. External calibration with standard weight
2
)  1� 1�9� 1 
    Function of C key    e.cal.usr. External calibr�/adjustment with user-defined weight
2
) 1� 1�9� 3 
    ο  Cal.Int. Internal calibration   1� 1�9� 4 
     Int.lin. Internal linearization (on analytical balances only)  1� 1�9� 5 
     Set.Prel. Setting the Preload  1� 1�9� 8 
     Del.Prel. Clearing the Preload  1� 1�9� 9 
     blocked C Blocked  1� 1�9�10
     Select  1� 1�9�12
     set.ext.w. Determine ext� calibration weight for e.cal.usr.  1� 1�9�17
  Cal.adj.ON  ο  Sequence adjustment  1� 1�10� 1 
     CAL.ADJ. Adjustment as needed  1� 1�10� 2
  Zero rng. Zero range    1 perc.ent  1� 1�11� 1
    ο  2 perc.ent  1� 1�11� 2
  INIT.ZERO Zero at Power On  ο  default Factory setting  1� 1�12� 1
     2 perc.ent  1� 1�12� 2
  On Tare Tare/zero at power on  ο  ON  1� 1�13� 1
     OFF  1� 1�13� 2
  CYC.rate Output rate  ο  normal  1� 1�14� 1
     highvar.  1� 1�14� 2
     slow  1� 1�14� 3
     medium  1� 1�14� 4
     fast  1� 1�14� 5
     veryfast  1� 1�14� 6
     maximum  1� 1�14� 7
  ISOcal Autom� calibration/adjustment    Off  1� 1�15� 1 
     Note  1� 1�15� 2
    ο  On  1� 1�15� 3
     To.w.linearization (for analytical balances only)  1� 1�15� 4
  EXT.Cal. External calibration 
1
)  ο  Free  1� 1�16� 1 
     Locked (blocked)  1� 1�16� 2
  cal.unit
1
)  ο  Gram  1� 1�17� 1 
    for calibration weight    Kilogr. Kilograms  1� 1�17� 2 
     USERDEF. (factory setting: pound)  1� 1�17� 4
  GEN.SERV.  men.Reset Menu reset    Yes Restore fcty� settings  1� 9� 1� 1 
  General servicing  (Factory Settings)  ο  no Do not restore settings  1� 9� 1� 2 
     Standard 
1
)   1� 9� 1� 3 
     Verifiable 
1
)  1� 9� 1� 4
 
1
) Not available on balances verified for use in legal metrology
 
2
) Not available on balances for use in legal metrology of accuracy class K