EasyManua.ls Logo

Satel Integra 32 - Page 77

Satel Integra 32
117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SATEL INTEGRA 75
new access codes in the system must be composed of at least 5 characters (USER CODE
MIN
. LENGTH parameter),
the following global options are enabled (cannot be disabled):
TROUBLE MEMORY UNTIL REVIEW,
DO NOT SHOW ALARM IF ARMED,
BLOCK KEYPAD AFTER 3 WRONG CODES,
WARN WHILE ARMING IF TROUBLE,
DISPLAY VIOLATED/BYPASSED ZONES ON ARMING,
DO NOT REPORT SATEL SERVER CONNECTION TROUBLE,
DO NOT REPORT TIME SERVER CONNECTION TROUBLE,
the following global options are disabled (cannot be enabled):
DO NOT ARM IF TAMPERED,
DO NOT ARM IF BATTERY TROUBLE,
REQUIRED SYSTEM RESET AFTER VERIFIED ALARM,
DO NOT ARM IF TROUBLE,
DO NOT ARM IF OUTPUTS TROUBLE,
DO NOT ARM IF REPORTING TROUBLE,
the TAMPER ALARM ALWAYS LOUD option is disabled for all zones, keypad and expander
buses (the option cannot be enabled),
the VALID WITHIN 60 SEC option is enabled for all partitions (cannot be disabled),
the entry delay time (global and for individual zones) can be up to 45 seconds (if longer,
it will be automatically reduced) for the 0. ENTRY/EXIT, 1. ENTRY, 2. DELAYED, 3. INTERIOR
DELAYED
, 85. ENTRY/EXIT CONDITIONAL, 86. ENTRY/EXIT FINAL, 94. ENTRY/EXIT
INTERIOR
and 95. ENTRY INTERIOR zone types,
the REPORTING DELAY option is enabled for the 4. PERIMETER, 5. INSTANT, 6. EXIT,
7. DAY/NIGHT and 64...79 BYPASSINGGROUP: 1...16 zone types (the option cannot be
disabled),
the ABORT DELAY option is enabled for the 0. ENTRY/EXIT, 1. ENTRY, 2. DELAYED,
3. INTERIOR DELAYED, 85. ENTRY/EXIT CONDITIONAL, 86. ENTRY/EXIT FINAL,
94. ENTRY/EXIT INTERIOR and 95. ENTRY INTERIOR zone types (the option cannot be
disabled),
the PRIORITY option is enabled for the 9. 24H TAMPER zone type (the option cannot be
disabled),
the AUTO-RESET 3 and AUTO-RESET 1 options are disabled for the 12. PANIC AUDIBLE and
13. PANIC SILENT zone types (the options cannot be enabled),
AC loss report delay (for the control panel and all modules with power supply units) can
be up to 60 minutes (if longer, it will be automatically reduced),
the quick arming is not possible (relevant parameters in keypads settings are
automatically modified),
the SHOW ARM MESSAGES option is enabled in all keypads (it cannot be disabled),
the following options are disabled in all keypads (they cannot be enabled):
SIGNALING TROUBLES IN PARTIALLY ARM,
SIGNAL NEW TROUBLE,
ALARM MESSAGES: PARTITIONS,
ALARM MESSAGES: ZONES,
SHOW VIOLATED ZONES,
DISPLAY MODE SWITCHING,

Table of Contents

Other manuals for Satel Integra 32

Related product manuals