4.1.14 Checking the safety valves
DANGER!
Risk of excess pressure build-up
Faulty or manipulated safety valves may lead to excess
pressure build-up. Excess pressure build-up may destroy the
system. There is then a serious risk of death in the vicinity of
the system due to flying parts and escaping hot gas, hot air
or hot cooling water in the case of water-cooled compres-
sors.
Check the safety valves regularly and replace if faulty.
Do not adjust, disable or remove safety valves.
CAUTION!
Risk of injury from safety equipment
Direct contact with safety valves can result in injury. When
blowing of
f a safety valve, hot air or hot gas escapes at high
pressure.
Wear the specified personal protective equipment to
minimise the risk of injury.
Avoid direct contact with the safety valves and maintain
a safe distance from them.
The safety valves are sealed by the manufacturer to prevent tampering. The
construction of the safety valves means that they cannot be tested for func-
tion.
The operator must check and replace the safety valves in accordance with
country-specific guidelines and laws.
Sauer USA offers a profes-sional and qualified safety valve
replacement service and corresponding training for
maintenance personnel. Please contact Sauer-Service.
Carry out the following checks to detect any damage to safety valves:
n Check the safety valve and seal for signs of external damage.
n Check threaded connections for proper seating.
n Check attached parts and lines for damage.
Have damage to safety valves, attached parts and lines repaired immedi-
ately by the Sauer-Service department.
MAINTENANCE