Savant IP Video with Audio Processing Deployment Guide
Copyright © 2018 Savant System, LLC
7 Best Practices
Once the system is installed and the configuration has been uploaded to the Host, there are a couple best practices to test a Savant IP Video system.
Initial Audio and Video setup/testing should be done using the default EDID. The default EDID has support for video resolutions up to 4k 60hz 4:2:0 8-bit.
Testing
Every source should be tested with every A/V zone. Savant recommends testing a single source with one A/V zone at a time.
1. Activate the first Video source to a single Zone.
2. Does Video pass?
a. NO: Check System Monitor for the resolution of the Input and then the output, Scale the VOM to 1080p.
If 1080p passes there may be an issue with either the TV or cabling. Replace HDMI cable and test again.
b. YES: Check Audio
3. Does Audio pass?
a. NO: In System Monitor set the audio path policy for the PAV-VOM to “Downmix”. If audio is still not present verify audio is enabled on the source.
b. YES: Continue to the next Zone.
4. Repeat with the same source until all Video zones have been tested. Repeat with all other Video sources in the same manner as shown above.
After this testing is complete. Add more advanced EDIDs and test again.