SCAIME Manual : NU-eNod4C-E-0418-196712-F.docx
Checkweigher Trigger level parameter
Checkweigher start
Level
0 Max.
capacity
The weight determination cycle can be started by a trigger level,
when the load cell signal reaches the specified value.
Result calculation settings
Stabilization time
0 6553 ms
During this time, measurements are not taken into account for
result calculation
Measuring time
0 6553 ms
During that time the signal is taken in account to calculate the
result.
Result correction
0.9 1.100000
Eventually used to adjust the checkweigher result.