4.5 Motor assembly and Anti-vibration rubber.
1) Disconnect the motor, RPM and motor temp cable.
2) Remove the 4 screws.
3) Disassemble the Motor assembly.
4) If you need, replace the Anti-vibration rubber.
4.6 RPM Sensor assembly
1) Disconnect the RPM Sensor cable from the Main PCB.
2) Remove the 2 screws(red circle).
3) Disassemble the RPM Sensor holder assembly.