Error messages and malfunctions
Display Cause Rectification
grinder left blocked
(sTxt-168)
- An object (e.g. a stone) is stuck in the
grinder.
Left espresso outlets are disabled
- Press the [RESET] button.
- If the message persists, disconnect the
espresso machine from the power mains.
Vacuum the coffee beans out of the
grinder. Check the grinder for stuck ob-
jects.
- If the problem still persists, contact an
authorised customer service representa-
tive.
grinder right blockd
(sTxt-169)
- See "grinder left blocked".
Right espresso outlets are disabled.
-
See "grinder left blocked".
grounds bin full
(sTxt-173)
- You can still serve 5 products before the
espresso machine gets blocked.
- Empty the coffee grounds container.
heating
(sTxt-172)
- When the espresso machine is switched
on, no products can be served until the
system warms up.
The espresso machine is blocked.
- You can dispense espresso and hot water
products after approx. 5 minutes.
- Check the phase fuse.
- If the message persists, contact a manu-
facturer-authorised customer service rep-
resentative.
heating steam
(sTxt-175)
- Excessive steam outputs.
- Phase fuse defective.
- Safety switch has opened.
Steam outputs are disabled other products
can be dispensed.
- You can dispense espresso and hot water
products after approx. 5 minutes.
- Check the phase fuse.
- If the message persists, contact a manu-
facturer-authorised customer service rep-
resentative.
level probe steam
(sTxt-191)
- The water level in the steam generator is
wrong.
Steam discharge is blocked.
- Check whether the stop valve of the water
mains is open.
- If the problem still persists, contact an
authorised customer service representa-
tive.
motor error
(sTxt-190)
- Control defective.
The espresso machine cannot be operated.
- Contact a manufacturer-authorised cus-
tomer service representative.
motor control
(sTxt-180)
- The control unit has recorded an error
function of the motor in the left brewing
unit.
Left espresso outlets are disabled.
-
Press the [Standby] button 2x and select a
espresso product, If the message persists,
contact a manufacturer-authorised cus-
tomer service representative.
>new programming!<
(sTxt-001)
- Data loss - Contact a manufacturer-authorised cus-
tomer service representative.
- Use the DATA SAVE chip card only after
previous arrangements have been made
with a manufacturer-authorized customer
service representative.
- Transfer data from the chip card to the
espresso machine
out let sensor brok
(sTxt-201)
- The machine is registering a failure in the
temperature sensor of the steam wand.
- Option, steam products can be used further
(Timeout).
- Contact a manufacturer-authorised cus-
tomer service representative.