Schwing ROCK - Replacement of Outlet Housing Lining (Kidney Plate) Plate

Default Icon
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE TRAINING
Service Manual
19
Rock Valve
Remove
p
ectacle plate
Securing Bolt
Guide/Support Rods
5. Pry the Spectacle Plate (Base Plate) away
from the pumping cylinders.
NOTE: In some old models, the tran-
sition pieces may come out with the
Spectacle Plate. If this becomes a
problem, see Service Bulletin G-104/
89 for assistance.
6. Thoroughly clean the area where the plate is
to be mounted, install the new Spectacle
Plate, and secure it. Reassembly requires fol-
lowing the above steps in reverse order.
Replacement of Outlet
Housing Lining (Kidney
Plate) Plate
Check the plate for wear, and if replacement is
necessary, follow these steps:
1. Remove the Keeper Bolt from the tension
nut using a 24 mm. wrench.
2. Remove the Tension Nut using a 60 mm.
wrench.
3. Remove the Setting Disc from the Rock
Pivot Shaft.
4. Remove the bolts from the End Cover and
insert the two Guide/Support rods into the
upper holes using a 36 mm wrench.
5. Slide the end cover along the inserted Guide
Rods.
6. To replace the lining, remove both Securing
Bolts in the End Cover using a 24 mm
wrench.