EasyManua.ls Logo

SEABOB CAYAGO VX2 - Powergrip Does Not Function Properly; Display Does Not Show Entire Image

Default Icon
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
| Page 68 | SEABOB Operation Manual |
7
7.6 Powergrip does not function properly
1. Remove dirt or foreign objects from the Powergrip by
rinsing it off with fresh water and / or blowing it out with
air from a low-pressure hose.
2. The Powergrip may freeze in frosty weather, causing
it to stick. Place the SEABOB in the water so that frozen
components can thaw off.
A damaged, sticking or bent Powergrip should
be repaired or replaced immediately. Contact the
manufacturer or your specialist dealer.
7.7 Display does not show entire image
Electrostatic discharge on the SEABOB may cause the
display to show only a portion of the full image (for ex
-
ample, only half the image). This can happen especially
when a person becomes electrostatically charged by
wearing rubber water shoes and then discharges the
electricity by touching the SEABOB, in particular around
the display.
If this occurs, briefly switch off the SEABOB completely
(Off mode or detach accumulator box ACS in a dry place),
and then switch it back on. This resets the SEABOB’s sys
-
tem and initiates an electronic self check. Afterwards, the
problem should be corrected. Electrostatic discharge is
only possible on land. It can never occur in water.

Table of Contents