KemiDose | pH · ORP · Chlorine
0000139024 rev. 1.0 EN
10
Set menu:
Press (3 seconds) and adjust set point value and press to confirm.
Calibration Menu:
Press (3 seconds) and calibrate probe pH, Chlorine, Temperature, ORP
System StandBy
Press (5 seconds) the system sets in StandBy mode; all functions are disabled.
Reset OFA Timer
Press (click) and reset countdown OFA time
Priming pumps
Only while the pump is in “stand-by mode” press down to reset flow totalizer,
to run pH pump, press
to run ORP/Chlorine pump, press to run Aux1 relay, press to run Aux2 relay
To restore the default parameters, follow the steps below:
Power off the KemiDose unit
Keep and pressed and power on the unit
The unit will flash Init.default__no
Press Init.default__Yes
Press to restore the default parameters.
Default parameters:
Language = EN
Set Point value = 7.4 pH; 700 mV; 1.2 ppm
Dosing method = Acid (pH); Low (Redox); Low (Cl)
OFA Time = OFF
Calibration = Full
Flow Input = OFF
Dosing type = PROP; ON/OFF Relay Aux1 e Aux2
1.2 ppm SetPoint
7.4 pH 720mV
ORP measure
pH measure
Free Chlorine
measure
Quick setpoint menu