KemiDose | pH · ORP · Chlorine
0000139024 rev. 1.0 EN
2
WARNING!
These products are DANGEROUS (IÓA) and require special precautions during use, handling and storage.
NEVER mix chemical products.
NEVER allow children or people who have not read this manual to use or tamper with KemiDose or any
of its peripheral components (including chemical products).
pH chemical products:
ABSOLUTELY not recommended => pure sulphuric acid
Recommended for lowering pH => negative pH (with a sulphuric acid base)
Recommended for raising pH => positive pH (sodium carbonate or bicarbonate)
ORP chemical products:
ABSOLUTELY not recommended => all types of organic chlorine
Liquid chlorine or 12% bleach can be used neat. If the product has a concentration of 48%, it is necessary to
dilute it in water in a 1:3 ratio.
The pH / ORP probes are subject to wear and tear and therefore are not covered by the warranty.
2. INSTALLATION INSTRUCTIONS
The probe’s angle of
inclination must never
exceed 45° from
vertical.
For optimum probe
reading, position it
perpendicular to the
tubing.
Probe positioning
Warning!
2 m
Make sure that the injection pressure is below 1.5 bar
Warning!
Installation plant